Create customized hermetic connections to transmit power and signal.
With the expansion of data utilization from factories to consumers, immersion cooling in data centers has increased in demand; to increase energy efficiency and density of components, server operators are employing fluorinated liquids such as Fluorinert™, Novec™, and Galden™ that are thermally conductive, chemically stable, non-flammable, and dielectric to cool the electronics in a compact space. A hermetic connection will ensure that the electrical connection is permanently sealed to a vacuum and/or positive pressure rating.
Depending on the IP (Ingress Protection) rating, an electrical connection might only protect from liquids under less permanent conditions as well as less harsh environments. Additionally, IP ratings are based on water. Variations in viscosity and compatibility are not involved in the IP-rating scale.
Several types of electrical connections are available. Douglas will source virtually any electrical connection type, such
as RJ45, QSFP, USB 3.0, C13, or fiber, and hermetically seal it within the housing assembly. Hermetic electrical connections
include connectors, wires, cables, power studs, busbars, printed circuit boards, fibers, or some combination thereof.
Our team will partner with you to source any components or connectors that are necessary to meet the application
requirements. Hermetic epoxy seals allow for the bonding of the epoxy between the housing and electrical connection with
minimal set up and tooling and as a direct interface.
Minimize signal loss and design constraints to create a hermetic feedthrough that meets fit, form, and function.
From a mechanical perspective, Douglas’ in-house machining capability allows for fast, easy integration of the housing
assembly into customer designs. From multi-connection plates to specialized housings, the materials and sealing
methods can be customized to customer specifications. Our standard hermetic feedthroughs utilize stainless steel, aluminum, or brass but are also available in almost any metal and many plastics. All assemblies are factory leak-tested and
hipot tested to customer specifications.
Fluorinert and Novec are trademarks of 3M;
Galden is a trademark of Solvay
Douglas Electrical has 75+ years of experience in the design & manufacturing of electrical & fiber optic connector & cable-based feedthrough solutions.
PotCon Series
OptiSeal Series
StudSeal Series
CircuitSeal Series
Including MIL-SPEC and Industrial
Portplate Series
Douglas Electrical Components, Inc.
5 Middlebury Blvd.
Randolph, NJ 07869
Phone: +1 (973) 627-4810